Gas Sensor, Explosion-Proof
Sensor modules are designed, and approved for installation and operation in hazardous locations. They may be used stand alone or with the DVP-120 Control Panel.
5100-02-IT Combustible Gas Sensor
The 5100-02-IT Combustible Gas Sensor Module utilizes catalytic bead sensor technology to monitor for combustible gases (methane and others). Output range is 0-100% of Lower Explosive Limit (LEL). Explosion proof, Class I, Div. 1, Groups B, C, D Class I, Zone 1, Group IIC, IP66, IP65, NEMA 4X II2 GD, Ex d IIC T6 = -40°C to 85°C
5100-XX-IT Sensors
The 5100-XX-IT Toxic Gas Sensor Modules utilize electrochemical sensor technology to monitor for a variety of toxic gases. Explosion proof, Class 1, Div. I, Groups B, C, D Group IIB + H2 IP66, IP65, NEMA 4X. Factory Mutual (FM) Approved for electrical safety and environmental parameters including Class I, Div. 1, Groups B, C, D and Class I, Zone 1, Group IIB+H2 IP66. The 5100-XX-IT is also SIL Certified and meets NFPA-72 requirements for gas detectors.
Sensor Types:
- Ammonia (NH3), 0-100 PPM
- Carbon Dioxide (CO2), 0-5000 PPM
- Carbon Monoxide (CO), 0-500 PPM
- Chlorine (CI), 0-10 PPM
- Chlorine Dioxide (CIO2), 0-3 PPM
- Hydrogen Chloride (HCI), 0-20 PPM
- Hydrogen Fluoride (HF), 0-10 PPM
- Hydrogen Sulfide (H2S), 0-100 PPM
- Methane (CH4), 0-100%
- Nitrogen Dioxide (NO2), 0-20 PPM
- Oxygen (O2), 5-25%
- Sulfur Dioxide (SO2), 0-100 PPM
5100-28-IT Sensor
The 5100-28-IT Combustible Gas Sensor Module utilizes Infrared (IR) Combustible Gas Sensor to monitor for combustible gases (methane and others). Output Lower Explosive Limit (LEL) or % volume . Explosion proof, Class 1, Div. I, Groups C, D Class I, Zone 1Group IIC, IP66, IP65, NEMA 4X, T6 TA = - 40°C to 85°C II2 GD, Ex d IICC
Common Features:
- FM Approval for performance and safety
- 6 month calibration interval
- 12 month calibration interval (5100-28-IT Sensor)
- SIL-2 certified
- Modbus RTU RS-485 interface
- 4-20 mA output
- HART Interface
- SMC Sentry digital bus interface
- ATEX Certified
- ATEX Approved (5100-05-IT)
- IECEx Certified (5100-05-IT)
- Optional Integral and Trouble alarm relays – Alarm, Warning and Trouble
- Aluminum or 316 Stainless Steel enclosure
- Non-intrusive calibration
- Integral scrolling LED display
- Optional remote sensor
- Remote alarm reset capable
- 90mA @ 24Vdc power consumption
NOTE: For facilitating regular calibration cycles, use the Calibration Gas Delivery Fitting when the Gas Sensor is mounted on a hard to reach area.